Shows & Exhibitions
   HB&R National Show
     2010

   HB&R Northern 2010
   HB&R National 2009
   Building into the
     Basement


News
   # BS 8102, 2009 #
   Basement -
     Housebuider



The Basement Information Centre
Riverside House
4 Meadows Business Park
Station Approach
Blackwater
Camberley
Surrey GU17 9AB

Tel: 01276 33155
Fax: 01276 606801

Email: info@tbic.org.uk

Case study

  Ref:
  104
  Title:
  Keeping Dry on the River
  Provided by:
  David Ball Group plc
  Summary:
  Watertight basement for Blackfriars Hotel In an imaginative design by architects, Franklin Associates, for a private underground art gallery in London, the specification of the self-compacting, waterproof-concrete mix used in the structure was cr
  For more information:
  sales@davidballgroup.com

  , was used in a 1 metre to 1.2 metre perimeter strip of concrete to create the required impermeable zone to prevent damp penetrating floor slabs to the public areas below ground. Completely compatible with regular concrete in use by framework contractor, John Doyle Construction, the specially designed mix was supplied to the site by RMC Readymix London from its batching plant at Vauxhall.

Within the system, consisting of a secant pile wall behind an inner concrete skin wall and drained cavity construction, David Ball Group waterproofing admixture, PUDLO CWP

A feature of the contract was the top down method of construction that took place behind the retained elegant facade of the original building. To facilitate this process during casting, access holes were left in the slab to enable remaining work to continue on extensive excavation and concrete placement below ground as eight floors of guest accommodation were created in the void above.

Despite the problems of creating a watertight structure near to the river, and meeting English Heritage and other planning requirements associated with the preservation of important external architectural features, the net result was that PUDLO CWP was easy to use and entirely compatible with other mixes.

The underground areas are dry and warm and no moisture has permeated through the complex sub-structure.

Using a waterproofing admixture it is possible to create a completely water resistant basement fulfilling grade 4 of Table 1 BS 8102:1990. The modified concrete issufficiently watertight to make membranes and drainage systems unnecessary.

 Within the system, consisting of a secant pile wall behind an inner concrete skin wall and drained cavity construction, David Ball Group waterproofing admixture, PUDLO CWP